A
ABS
- Black plastic pipe and fittings. Generally used in waste water and drainage
systems. Introduced in the 1960's, popular for new residential construction
and remodeling.
AIR
CONDITIONING - The process of treating air to simultaneously control its
temperature, humidity, cleanliness and distribution.
AIR
FILTER - A furnace filter installed in line with the cold air return which
filters out dust and debris and prevents its re-entry into the occupied
interior.
AIR
RETURN - A furnace duct through which interior cool air returns to the
furnace. This cool air is then circulated through the heat exchanger,
warmed, and distributed through the ducts.
AIR
POCKET/BLISTER - A bubble in the roofing surface formed by water vapor
expanding between the layers of a built-up roofing membrane. This condition
can reduce the useful life of the roofing surface and is conducive to
moisture penetration and subsequent leakage.
ALUMINUM
WIRING - A type of conductor used to carry current. The U.S. Consumer
Product Safety Commission has determined that aluminum wiring used in
120 Volt light and outlet circuits can be hazardous and a cause of fire.
A failure can occur because aluminum wire behaves differently than copper
wire when current travels through the conductor. An aluminum wire will
expand and contract more than a copper wire. The expansion and contraction
can result in loose connections. The loose connections can oxidize. The
loose, oxidized connections can spark or overheat when current flows to
the connection. The spark or overheating can cause a fire. This potential
problem has nothing to do with the wires in the walls, floors or ceilings.
This problem occurs only at the connections. It is possible to control
and repair this condition. Typically, aluminum is no longer used in the
individual branch lighting and receptacle circuits. It is still commonly
used and approved to bring power to a structure and to energize the distribution
panels as well as power the individual appliance circuits. Aluminum wire
should only be connected to listed and rated devices (breakers, outlets,
switches, etc.). Additionally, these devices should have an anti-oxidant
installed to cover the connections. As a preventive measure, each accessible
aluminum connection should be periodically checked by a licensed electrician
to insure that it is securely fastened. If aluminum wiring has been installed
in the individual lights, switches and receptacles, we recommend repair
with crimp connectors. This repair consists of attaching a short length
of copper wire onto the existing aluminum wire with a specially designed
metal sleeve and an air-powered crimping tool. This makes a permanent
connection that is, in effect, a cold weld. An insulating sleeve is heat
shrunk around the crimp connection to complete the repair. This is in
accordance with the recommendation of the U.S. Consumer Product Safety
Commission.
AMBIENT
TEMPERATURE LESS THAN 65 DEGREES - The temperature of the air surrounding
air conditioning equipment should be at least 65 degrees for 12 hours
before the equipment is operated. Operating the compressor in cold temperatures
can severely damage the compressor.
AMP
- Short for Amperes. The rate of flow of electricity through wire.
ANCHOR
BOLT - A bolt used to secure a wooden sill plate to a concrete or masonry
floor or wall. The purpose of the bolt is to limit the ability of the
framing to move independent of the foundation in the event of seismic
activity.
ANGLE
STOP - A shut-off valve arranged in a 90-degree configuration. It is used
to shut off the flow of water to a fixture. A double angle stop is an
angle stop that controls both the hot water to the sink faucet and to
the dishwasher. As a preventive measure, we recommend the installation
of a separate fixture shut-off valve for the dishwasher. This will allow
for the uninterrupted use of the kitchen sink in the event of necessary
repair or removal of the dishwasher.
ANTI-SIPHON
VALVE - A device installed on irrigation piping designed to prevent the
drawing of contaminated ground water into the domestic water supply system.
ASBESTOS
- Asbestos is a naturally occurring mineral fiber extensively used in
construction. Nearly every building contains asbestos in some form. It
may be found in vinyl flooring, patching compounds and textured paints,
sprayed acoustic ceilings, acoustic ceiling tiles, stove insulation, furnace
insulation, pipe insulation, wall and ceiling insulation, roofing, shingles
and siding as well as appliances. Exposure to asbestos can be a serious
threat to one's health. There are a number of choices available for dealing
with asbestos. They include leaving it alone, encapsulation and abatement.
Removal of this material is a specialized procedure and should be attempted
only by a qualified and licensed expert. Information regarding identification
of asbestos, its hazards and safe removal may be obtained from the U.S.
Consumer Product Safety Commission, Environmental Protection Agency and
other governmental agencies.
AUTOMATIC
SAFETY CONTROLS - Devices designed and installed to protect systems and
components from excessively high or low pressures and/or temperatures,
excessive electrical current, loss of water, loss of ignition. fuel leaks,
fire, freezing, or other unsafe conditions.
AUTOMATIC
GARAGE DOOR OPERATOR DOES NOT REVERSE - The garage door was tested and
did not automatically reverse. This indicates that the door opener does
not have an auto-reverse mechanism, it is broken or it needs adjustment.
We recommend that the opener be modified, replaced or adjusted as necessary.

B
BALLOON
FRAMING - A type of framing system where the studs extend from
the sill to the roof.
BLOWER
- A fan in a furnace or air conditioning unit which blows air through
ducts.
BLOWER
BEARINGS WORN - The forced-air furnace fan bearings are worn.
The fan bearings should be lubricated if possible. Damaged bearings may
need to be replaced. It is possible that the fan itself may need replacement.
BOILER
- A heating device which heats hot water or creates steam for circulation
in heating pipes, radiators. Baseboards or convectors.
BOILER
LEAKS - Boiler leaks must be repaired or there may be a loss
of heat and the boiler may be damaged beyond repair.
BRASS
GAS CONNECTOR - Brass is made of zinc and copper. The sulfur
in the natural gas reacts with the copper and can cause the piping to
become brittle, deteriorate and leak. We recommend that this tubing be
removed and replaced with an approved gas supply connector.
BREAKER
BRIDGE MISSING - A 240 volt double pole breaker installed without
a bridge between the two pole handles. We recommend that this breaker
be bridged. This will insure that all of the power is shut off to this
circuit if the overcurrent protection device is tripped.
BRIDGING
- Short, structural members criss-crossed between floor or ceiling joists
to provide reinforcement and distribution of stress.
BRITTLE
SURFACE - The roofing surface is brittle and subject to breakage.
This condition is an indication of age and suggests that the roofing surface
is near the end of its useful life.
BROKEN/FRAYED
SASH CORDS - The cords along each side of a double hung window
which are attached to counter weights in the wall. The sash cords hold
the window open. The window will not stay open by itself if they are broken.
Frayed sash cords are likely to break. These sash cords should be replaced
to ensure that the windows remain operable.
BTU
- British Thermal Unit, a unit of measure of heat. One BTU is the quantity
of heat needed to raise the temperature of one pound of water one Fahrenheit
degree.
BURIED
FUEL OIL TANK - We found evidence to suggest the presence of
a buried fuel oil tank. Removal of such tanks and soil testing may be
required. A determination as to the presence and condition of buried tanks
as well as possible soil contamination is beyond the scope of our inspection.

C
CAULK/SEAL
GAPS - Gaps in the exterior of the building around the doors,
windows and plumbing and electrical entry points. All gaps should be caulked
and sealed to prevent heat loss, air infiltration and moisture entry.
CELLULOSE
DEBRIS - Scrap-wood found in the substructure soil area. This
debris can result in the infestation and infection of wood-destroying
pests and/or organisms. It should be removed.
CIRCUIT
- The path of electricity away from and back to its source.
CIRCUIT
BREAKER - An overcurrent protection device which automatically
opens an electrical circuit when too much current flows through the conductor.
COMPRESSOR
- A pump which forces refrigerant through an air conditioning system.
COMPRESSOR
SHORT CYCLES - A suspected compressor defect. A qualified air
conditioning contractor should be contacted to evaluate the air-conditioning
system and determine the corrective measures needed.
CONDENSATION
- In a building: Beads or drops of water that accumulate on the inside
of the exterior covering of a building when warm, moisture-laden air from
the interior reaches a point where the temperature no longer permits the
air to sustain the moisture it holds. The use of louvers or attic ventilators
will reduce moisture condensation in attics. A vapor barrier under the
gypsum lath or dry wall on exposed walls will reduce condensation in them.
A plastic vapor barrier over damp subarea soil will help create a dry
air space between the damp soil and the floor framing, thereby helping
to limit the amount of moisture that is able to rise into the framing,
and reducing the possibility of future damage and deterioration.
CONDUCTOR
- An electrical wire capable of carrying current.
CONDUIT
- A hollow pipe (metal or plastic) casing through which electric wires
run.
CONVECTION
- The transfer of heat by the motion of the heated matter.
COPPER
GAS CONNECTOR - Sulfur in natural gas reacts with copper and
can cause the connector to deteriorate and leak. We recommend that copper
tubing be removed and be replaced with an approved gas supply connector.
CRACKED
HEAT EXCHANGER - A fracture in the walls of the furnace combustion
chamber. The heat exchanger separates the flame and combustion products
from the air chamber. A crack in the heat exchanger may allow the products
of combustion to enter the occupied interior. One of the products of combustion
is carbon monoxide. In addition to carbon monoxide, natural gas combustion
produces formaldehyde gas. Depending on the authority and study published,
acceptable levels of carbon monoxide and formaldehyde gas in an indoor
environment vary greatly. There are a number of testing methods practiced
to determine if a heat exchanger is cracked. They can be reduced to a
two step process. First, a visual inspection with a flashlight can reveal
a crack, which can be confirmed by feel to insure that it is not simply
discoloration or distortion. Another first step is flame observation.
The furnace flame is observed before and after the circulating air comes
on. Floating flames, flame rollout and flame distortion can indicate a
failure of the heat exchanger. The second step is tracer gas. A tracer
gas is injected into the combustion chamber and a calibrated gas detector
is used to check for the presence of the tracer gas on the air side of
the heat exchanger. Neither visual inspection nor flame distortion should
be used to confirm the other. Although a tracer gas test would be necessary
to verify observations made visually or by flame and determine actual
levels of carbon monoxide or formaldehyde gas, our experience has shown
that identification of a crack by visual inspection is sufficient to recommend
that the furnace be repaired or replaced. Although it may be possible
to repair or replace the heat exchanger, it is usually not considered
cost effective, and parts may be difficult or impossible to find. The
most common course of action is to replace the furnace.
CRACKED
MASTIC - Cracks in the roof cement coating used to seal the roof
connections and penetrations. This creates a condition conducive to moisture
penetration and subsequent leakage. We recommend that these areas be repaired
as necessary to prevent leakage.
CRACKED/DETERIORATED
MORTAR - Cracks and deterioration in the mortar used to seal
the tile roof joints. This creates a condition conducive to moisture penetration
and subsequent leakage. Cracked and deteriorated tile mortar should be
replaced.
CRACKS
IN INTERIOR WALLS/CEILINGS - Hairline cracking in the interior
walls and ceilings, as well as minor sloping and sagging of floors and
door casings, should be expected as a result of ordinary settlement and
expansion of the foundation system, structural framing, and soil. These
conditions do not, in our opinion, represent a failure of the framing
system. We are not registered engineers. Additional information concerning
settlement of the structure and building, site, would have to be obtained
by retaining a qualified registered engineer.
CREOSOTE
- One of the by-products given off when burning wood. Creosote condenses
on the walls inside the fireplace chimney. It is highly combustible and,
if sufficiently heated, can ignite and start a flue fire. Fireplaces and
chimneys should be cleaned annually or when one eighth to one quarter
of an inch of creosote accumulates.
CURRENT
- A flow of electric charge.

D
DAMAGED
CONDUCTOR INSULATION - We found damaged service conductor insulation.
We recommend that all exposed conductors be repaired or replaced as necessary.
DAMAGED
RAFTERS - Damage to any of the parallel beams that support a
roof. All damaged rafters should be reinforced or replaced. Sometimes
the rafters extend beyond the exterior walls. These rafter tails are subject
to moisture damage. They must be maintained or damage will result.
DAMAGED
SHEATHING - Damage to the material used to cover the outside
wall of a frame house or a timber roof. We recommend that all damaged
material be replaced.
DAMAGED
WINDOW FRAMES - Damaged windows are often a result of deferred
maintenance. We recommend that all damaged window,, he repaired or replaced
as necessary.
DEAD-FRONT
- Switches, circuit breakers, switchboards, control panels and panel board
fronts must be covered so that no current-carrying parts are exposed.
This cover is called a Dead-Front.
DEBRIS
ON ROOF OR IN GUTTERS - Gutters filled with debris should be
cleaned to ensure proper drainage. Roofing surfaces covered with debris
should be cleaned not only to ensure proper drainage but also to prevent
premature deterioration of the roof surface.
DECK
MOISTURE MEMBRANE FAILED - See moisture membrane.
DECK
RAILING UPGRADE - We recommend that all decks and landings 30
inches or more above the ground have a railing. The railing should be
at least 36 inches high and the spacing between the railing pieces should
be no more than four inches.
DOUBLED-UP
BRANCH CIRCUIT - Two circuits controlled by one overcurrent protection
device. This wiring method increases the possibility of tripping the overcurrent
protection device. Each circuit should be separately fused with an overcurrent
protection device of appropriate amperage.
DOWNSPOUT/GUTTER
LEAKS - A leaking gutter or downspout can allow water to penetrate
a sidewall and enter the occupied interior through a foundation wall or
slab. Deteriorated gutters and downspouts should be repaired or replaced
as necessary.
DRIP
LOOP - A loop in each of the overhead electrical service entrance
conductors designed to prevent the passage of moisture into the weatherhead
service raceway or equipment.
DUCTS
- Metal piping used for distributing warm or cool air.

E
EARTH-WOOD
CONTACT - Wood in contact with dirt. This condition is conducive
to the infestation and infection of wood-destroying pests and/or organisms.
We recommend that all earth-wood contacts be broken and any damaged or
deteriorated material be replaced.
EAVE
- The part of the roof which extends beyond the sidewall.
EFFLORESCENCE
- A deposit of soluble salts, usually white, on the surface of concrete
and masonry walls due to evaporation of water.
ELECTROMAGNETIC
RADIATION - Electromagnetic fields are produced by alternating
current in electric wires. There are two components: an electric charge
and a magnetic force, resulting in electromagnetic radiation. High current
power lines are a source of electromagnetic fields. Studies have suggested
a possible increase in leukemia, cancer and miscarriages from exposure
to electromagnetic radiation. Studies are currently in progress to help
quantify the risks. More information can be obtained from the local utility
company, U. S. Department of Energy (202) 586-5000 and the U. S. Environmental
Protection Agency (202)260-7676.
EXPOSED
AND ACCESSIBLE - Our inspections are limited to a visual review
of those areas of the premises which are exposed to view. Any area which
is not exposed to view, or is otherwise inaccessible because of soil,
walls, floors, ceilings, carpets, furnishings, storage, or any other things,
and is concealed, is not included in our inspection. Our inspection does
not include any destructive testing or dismantling of equipment, systems,
or surfaces. With access and an opportunity for examination, reportable
conditions maybe discovered. If inspection of inaccessible areas is desired,
this will be performed upon arrangement at an additional cost to the interested
parties at such time as access can be provided.
EXPOSED
WIRING - Wiring or connections not properly covered and protected.
We recommend that all of these connections be repaired and be properly
protected.
EXPOSED
ROOF FASTENERS - An indication of significant roofing surface
wear or poor installation. This creates a condition conducive to moisture
penetration and subsequent leakage into the occupied interior. All exposed
fasteners should be covered.
EVAPORATION
COILS - The part of the air conditioning system where the refrigerant
returns; to gaseous form. Frequently located in the furnace plenum.

F
FAILED
- Something that no longer functions as designed or intended.
FASCIA
- A flat, vertical board enclosing the overhang, under the eave that runs
along the roof edge.
FELT
EXPOSED/WORN - An indication of significant roofing surface wear.
Prolonged exposure to the sun can damage the felt. Damaged felt can result
in moisture penetration and subsequent leakage into the occupied interior.
The deteriorated roofing surface should be repaired, all damaged felt
replaced, and exposed felt covered.
FIRE-RESISTIVE
BARRIER - A fire-resistive separation barrier. Fire-resistive
walls may not have been required at the time of construction. Present
building code requires a one-hour fire-resistive barrier between the garage
and the occupied interior. The purpose of this barrier is to prevent the
spread of fire from the garage into the living areas. Flammable liquids
are often stored in the garage. The risk of a fire starting in the garage
is significant enough to warrant recommending that a one-hour fire-resistive
barrier be installed.
FLASHING
- Material used at connections and penetrations in a roof or wall to prevent
leakage.
FLASHING
DEFECTIVE - Flashing installed improperly which creates a condition
conducive to moisture penetration. The connections and penetrations must
be repaired to prevent leakage.
FLASHING
INADEQUATE -Insufficient flashing. This condition often leads
to leakage. We recommend that all to door, window, deck and roof connections
and penetrations be properly flashed to prevent moisture penetration.
FLATWORK
- A concrete or asphalt surface such as a sidewalk, driveway or patio.
Any cracks should be patched and any holes or gaps filled. The flatwork
should be examined periodically for signs of failure or further deterioration
and repairs made if necessary. Replacement may be necessary at some point
in time.
FLEXIBLE
GAS CONNECTOR - Older installations of gas-fired appliances often
use rigid gas piping. This piping is subject to damage in the event of
support movement. We recommend that all gas-fired appliances be equipped
with flexible gas connectors or swing joints as appropriate. This should
help reduce damage in the event of an earthquake.
FORCED-AIR
SYSTEM - A heating system in which air is heated in a furnace
and distributed through a structure aided by a blower.
FORMALDEHYDE
- Colorless, pungent gas used as raw material in manufacture of particle
board, decorative paneling, fiberboard, wafer board, carpeting, permanent-press
fabrics and foam insulation. Heat & humidity increase the level of
emission, however, the rate diminishes as materials age. The U.S. Environmental
Protection Agency classifies formaldehyde as a possible carcinogen. Formaldehyde
can also irritate the eyes, nose and throat, and cause headaches and dizziness.
Formaldehyde levels can be reduced by increasing ventilation, reducing
temperature and humidity and reducing the number of new pressed-wood products
in a home. Removal of wood paneling or subflooring is sometimes necessary.
More information is available from the U. S. Environmental Protection
Agency (202)260-2080.
FORM-WOOD
- Wood used in the forming of a concrete foundation or retaining wall,
typically removed after the concrete has set. If it is left in place,
it can lead to the infestation of wood-destroying pests. We recommend
that all form wood be removed.
FOUNDATION
- Construction below or partly below grade, which provides support for
exterior walls or other structural pans of the building.
FOUNDATION
OUTDATED - An old foundation that is weak and subject to failure
because of its age, condition and design. A brick foundation would be
an example. Although an outdated foundation may not have failed, it is
likely to be severely damaged in the event of seismic activity and is
more susceptible to moisture damage. Replacement may not be necessary
now, but may be necessary at some point in the future. Unfortunately,
it is difficult to determine when to act. Obviously, if one waits until
it fails, one waited too long.
FROZEN
FIXTURE SHUT-OFF VALVES. - Plumbing shut-off valves that no longer
turn. This occurs when the valves are seldom operated. An inoperable valve
prevents the water from being turned off if it is necessary to repair
the fixture. We recommend that they be repaired and be made operable again.
FUNCTIONAL
DRAINAGE - A plumbing drain is functional when the fixture empties
in a reasonable amount of time, and does not overflow when another fixture
is drained simultaneously.
FUNCTIONAL
FLOW - A reasonable flow at the highest fixture in a dwelling
when another fixture is operated simultaneously.
FUSE
- An overcurrent protection device with a circuit opening fusible member
directly heated and destroyed by the passage of too much current through
it.
FUSED
NEUTRAL - Where an electrical neutral wire is fused. If the fuse
on the neutral wire blows, the circuit will be open, and the fixtures
and/or appliances on this circuit will not function. However, power will
still be present through the circuit, right up to the outlet. This creates
a shock hazard. We recommend that this condition be corrected.

G
GABLE
ROOF - A roof with two pitches, designed to provide more space
on the upper floors.
GALVANIZED
PIPE - Steel pipe with a protective zinc coating. Used for supply
of domestic water and waste and vent piping.
GARAGE
DOOR SPRINGS - Prior to 1976, the counter balance springs used
for tilt-up garage doors were not provided with a safety device to control
spring breakage. Without the benefit of a safety device, it is possible
that pieces of the spring may fly across the garage upon accidental breakage.
We recommend that the garage door be springs be upgraded.
GATE
VALVE - A shut-off valve using a rising disc (gate) to control
liquid flow.
GFCI
- Ground Fault Circuit Interrupter: a safety device which monitors the
difference between current flowing through the hot and neutral wires of
a receptacle. If there is an imbalance of current greater than five milliamps,
the current will be cutoff in less than a second. GFCI protection is recommend
in the garage, outdoor and bathroom receptacles. We also recommend that
all pool and spa equipment have GFCI protection. We further recommend
that all kitchen receptacles within six feet of a sink be equipped with
GFCI devices. This will reduce shock and short hazards.
GRADE
- The ground level around a structure. When the ground is less than six
inches below the top of the foundation, it is considered a marginal grade.
A faulty or marginal grade can lead to moisture damage and/or pest control
problems. If damage Is discovered, we recommend that the height of the
foundation be raised to a minimum of six inches above the ground and that
all damaged material be replaced. If no damage is present, we recommend
that this area he periodically reviewed by a qualified individual for
signs of drainage. Repairs should be made if necessary.
GROUND
CONDUCTOR SPLICES AND LOOSE CONNECTIONS - The system ground is
ineffective because of splices and loose connections in the grounding
conductor. We recommend that the grounding conductor be repaired or replaced
as necessary.
GROUND
RECEPTACLES - A random sampling of individual receptacles found
these to be operable but some are not grounded. We recommend that all
kitchen, bathroom, outdoor, garage and interior three-pronged receptacles
be properly grounded in accordance with current building practice.
GROUNDED
- A conducting connection, whether intentional or accidental, between
an electrical circuit or equipment and the earth, or to some conducting
body that serves in the place of the earth.
GROUND
WATER CONTAMINATION - Ground water can be contaminated from leaking
underground storage tanks, illegal dumping, poorly contained landfills
or hazardous waste spills. Contaminated ground water can be hazardous
to one's health if it used for gardening or irrigation. Qualified individuals
would have to be retained for evaluation and a determination of what corrective
steps may be necessary.
GUSSET
- A strap made of metal or wood attached at the connection of roof trusses
or rafters or foundation area beams and posts. Gussets will help limit
the framing's ability to laterally rack in the event of high winds.

H
HEAT
EXCHANGER - A device by which heat is exchanged from one heat-carrying
medium to another without direct contact between the two media.
HIP
ROOF - A roof with no gables; usually has inclined planes on
all four sides of the building.

I
INACCESSIBLE-
Any area which is not exposed to view or is concealed because of soil,
walls, floors, ceilings, carpets, furnishings, storage, or any other things
is inaccessible. Inaccessible areas are not included in this inspection.
Reportable conditions may be present in inaccessible areas. If review
of inaccessible areas is desired, this will be performed upon arrangement
at an additional cost to the interested parties at such time as access
can be provided.
INADEQUATE
FOUNDATION CLEARANCE - Foundation area clearance between the
soil and the wooden framing which is less than eighteen inches. Insufficient
clearance does not allow access for inspection or maintenance and creates
a condition conducive to moisture damage and decay of wooden members.
We recommend that a minimum of eighteen inches of clearance be provided
between the soil and the framing. Any damaged wooden material found in
the course of this work should be replaced.
INADEQUATE
CLEARANCE TO COMBUSTIBLES - Gas-fired appliance vents must be
far enough away from combustible surfaces to prevent the heat that these
vents carry from causing a fire. Single wall vents should be at least
six inches away from combustible surfaces and double wall vents should
be at least one inch away.
INADEQUATE
COMBUSTION AIR - The oxygen-carrying air which fuel burners need
to operate safely. It Is normally supplied through venting ducts or openings
in walls or doors. We recommend that additional venting be installed.
INADEQUATE
FOUNDATION DRAINAGE - Continuous foundation area moisture accumulation
causes damage and/or deterioration to the foundation and/or framing. We
recommend that the drainage be upgraded as necessary to collect the surface
and subsurface moisture approaching the foundation and route it to some
central drainage collection point. All damaged foundation and framing
should be repaired or replaced as necessary.
INADEQUATE
ROOF DRAINAGE - Significant roof ponding can indicate inadequate
drainage. Standing water can result in leakage. We recommend that the
drainage be upgraded as necessary to properly collect and divert water
off of the roof.
INSUFFICIENT
ROOF SLOPE - A shingle type roofing surface applied over framing
whose pitch is less than three inches in twelve inches. This means that
for every twelve horizontal inches the roof fails to rise at least three
inches. This roofing surface is subject to leakage because of poor drainage.
We recommend that the roof be periodically checked for signs of moisture
penetration and patched and sealed as necessary to prevent leakage and
subsequent damage. At such time as replacement of this roofing surface
is made, we recommend the installation of a conventional built-up or single
ply roofing membrane.
INSULATION
INSTALLED BACKWARDS -Insulation installed with the vapor barrier
pointed away from the living space. This can cause a buildup of moisture
and subsequent damage. We recommend that this insulation be repaired and
installed with the vapor barrier pointed toward the heated side of the
building. Any damaged material found in the course of this work should
be replaced.

J
JOISTS
- Parallel, horizontal boards laid edgewise from wall to wall to support
the boards of a floor or ceiling.

L
LAMPCORD
WIRING - Unapproved extension cord wiring running along the outside
of finished walls, floors or ceilings (sometimes referred to as zipcord
wiring). It is easy to overload the wire and the wire is subject to physical
damage. All lampcord wiring should be removed. Additional convenience
outlets can be installed if desired.
LEAD
CONTAMINATION - Lead can be present outside a structure in the
soil as a result of automobile exhaust and exterior lead-based paint.
Lead paint may have been used on the outside of the building and have
found its way into the soil. Proximity to busy roadways can result in
automobile emissions elevating lead levels.
LEAD
PAINT - Lead-based paint is a hazard when paint chips and particles
and dust are ingested by children. Lead accumulates in the blood, soft
tissues and bones, leading to damage to the kidneys, brain and central
and peripheral nervous systems. Children are more susceptible to the toxic
effects of lead paint because lead is more easily absorbed into growing
bodies. Precautionary measures include removing lead from children's environment,
mopping floors and window sills to remove lead dust and washing hands
before eating. Abatement contractors must use extensive precautions to
prevent contamination from lead dust.
LEDGER
FLASHING MISSING - The ledger is a piece of horizontal lumber,
usually a 2 x 8 or 2 x 10 bolted or nailed to the exterior of a building.
Joists are attached to the ledger and the finished decking or stair landing
material is secured to the joists. Water seeping behind the ledger can
cause damage to the siding and franuing. Ideally, the ledger should be
flashed at the top edge to prevent moisture penetration behind the ledger
and around the ledger fasteners. A secondary method of dealing with this
condition is to keep the top edge of the ledger caulked and sealed as
well as applying caulking at the ledger fasteners. When the ledger is
replaced it should be properly flashed and sealed.
LOOSE/MISSING/WORN
SHAKES OR SHINGLES - A condition conducive to moisture penetration
and subsequent leakage into the attic and/or occupied interior. We recommend
repair or replacement as necessary to prevent leakage.

M
MAIN
DISCONNECT - A device by which the electrical system can be disconnected
from its source of supply. Six or more branch circuits require a main
disconnect device.
MASTIC
- Asphalt material used to seal around roof connections and penetrations.
MINIMAL
SURFACE PREPARATION - Premature weathering of painted and/or
stained exterior surface due to minimal surface preparation. Prior to
the next application of paint and/or stain, we recommend the exterior
be properly prepared.
MOISTURE
BARRIER - Treated paper or metal which retards or bars water
vapor. It is used to keep moisture from passing into walls and floors.
MOISTURE
MEMBRANE HAS FAILED - The moisture membrane has failed when water
has penetrated through the moisture barrier. There may be damaged framing
below. All damaged material must be replaced or the damage may spread.
Moisture must be prevented from penetrating the framing or additional
damage will occur. Our primary recommendation is to install a new moisture
membrane. This will stop any further leakage and subsequent damage. It
may be possible to seal the surface above, thereby, hopefully stopping
further water penetration. However, there is no guarantee that sealing
the surface will work and this repair will require frequent maintenance.
MOSS
BUILDUP - Moss retains moisture and can damage the roofing surface.
We recommend that the moss be removed.
MULTIPLE
LAYERS - Multiple roofing surfaces add extra weight to the roof
framing. Too much weight can crack framing members. Most local building
departments limit the number of roofing surfaces to three. Some, however,
limit it to two. Another problem that can occur with multiple roofing
surfaces is the inability to effectively seal the roof connections and
penetrations, a critical component of the roofing system. When multiple
surfaces are present, the usual way to seal the connections and penetrations
is with a plastic roof cement coating. Unfortunately the plastic roof
cement coating does not last as long as the roofing surface and requires
more frequent maintenance than metal flashing. At such time as replacement
of the roofing surface is made, we recommend that all of the existing
roofing surfaces be removed, the framing resheathed as necessary and all
roof connections and penetrations reflashed before the new surface is
installed. This will help reduce the weight on the framing and the possibility
of cracking as well as prolong the useful life of the new roof.
MULTI-WIRE
BRANCH CIRCUIT - An electrical circuit consisting of two or more
ungrounded conductors having a potential difference between them and a
grounded conductor having, equal potential difference between it and each
ungrounded conductor. This type of circuit is commonly used to energize
the dishwasher and garbage disposal outlet located in the sink base cabinet.
A common problem arises when both hot conductors of the circuit are connected
to the same pole or leg of the distribution panel. If both the dishwasher
and disposal are operated at the same time, the breaker protecting the
circuit will not trip. This is a potential hazard and the circuit should
be repaired.

N
NEGATIVE
GRADING - Grading which is sloped toward the structure. Low spots
and negative grading will increase the chances of water penetration through
the foundation and subsequent pooling or puddling in the basement, garage
and/or subarea. We recommend that the site be regraded as necessary to
make sure that surface water runs away from the structure. Any damaged
material found in the course of this work should be replaced.
NO
SAFETY GLASS - A random sampling of exterior doors and windows
and review of individual shower doors, it revealed some areas which lack
safety glass. This is not uncommon in older buildings as safety glass
may not have been required at the time of installation. Doors and windows
not equipped with safety glass are hazardous if broken. Present industry
standards require safety glass to minimize this hazard.
NO
SIGN OF SIGNIFICANT NON-PERFORMANCE - Capable of being used.
NOT
PRESENT - Not installed.
NO
UNDERLAYMENT - A tile roof installed directly over the sheathing
without an underlayment. An underlayment provides a moisture barrier between
the tile and the attic. The manufacturer's specifications may permit this
method of installation; however, it is our opinion that without an underlayment,
this roof is subject to premature leakage. We recommend that the tile
surface and the connections and penetrations be periodically examined
by a qualified and licensed roofing contractor for signs of damage and
leakage and repairs be made if necessary.

O
OUTLET
(ELECTRICAL) - A switch, light or receptacle.
OVERFUSED
- A fuse or breaker too large for the rated capacity of the circuit. This
allows too much current to flow through the conductor (wire) before the
overcurrent protection device blows or trips. This is hazardous. The rated
capacity of the circuit may not have been exceeded yet. However, increased
demand on the circuit may result in the conductor overheating which can
cause a fire. We recommend that all overfused branch circuits be repaired
and equipped with overcurrent protection devices of appropriate amperage.
P
PAINT/STAIN
WEATHERED - Portions of the exterior are weathered, exposed and
subject to damage. We recommend that all exposed areas be sealed to provide
protection against inclement weather. Prior to the next application of
paint and/or stain, we recommend that the exterior be properly prepared.
PANEL
RUSTED - All rusted panels should be primed and sealed to prevent
further deterioration.
PARAPET
WALL - The part of the sidewall of a structure which extends
above the roof line.
PARGING
- A coat of cement over block foundation walls, or a coat of plaster over
stone or brick walls.
PENETRATIONS
- Any projection through a roofing surface necessitating flashing, such
as plumbing vents and skylights.
PLATFORM
FRAMING -A type of framing where each story is built on a platform
and the studs run the height of each story.
PLENUM
- A large duct or air chamber in which the hot air from the furnace is
distributed to the ducting and through the ducts to the registers.
POINT-UP
MORTAR JOINTS - To fill and finish the joints between bricks
with cement or mortar. Often called Tuck Pointing. We always recommend
that this work be done by experienced professionals.
POLARITY
REVERSED - An electrical receptacle which has been wired with
the hot and neutral wires reversed. Reversed polarity can compromise the
grounding of an appliance and cause some electrical equipment to operate
improperly. We recommend that the polarity be corrected.
PULL
CHAIN LIGHT NEAR WATER - Pull chain lights in rooms with running
water are dangerous. Their proximity to running water creates a shock
hazard. We recommend that these lights be equipped with approved and grounded
switches.
PVC
- Rigid white plastic pipe and fittings used for supply of domestic water
and yard sprinkler systems and in interior drain, waste and vent systems.
Introduced in the 1960's.

R
RADON
- Radon is a colorless, odorless gas that occurs as part of natural decay
of uranium. Radon is present to some extent in all soils and groundwater
and its levels vary within geographic areas. Radon is classified by the
U.S. Environmental Protection Agency as a known carcinogen. There are
no immediate symptoms resulting from exposure to radon. Most radon enters
the home through cracks and openings in concrete slabs, crawlspaces, sumps
and the tiny pores in hollow-wall concrete blocks from the soil underneath.
Sometimes radon enters homes through well-water. The level of radon can
be measured and mitigation measures taken if necessary. Contact the Colorado
Department of Health Radon Program for a list of radon testing laboratories
and mitigation contractors who meet federal requirements. Additional information
may be obtained from the U.S. Environmental Protection Agency.
RAFTER
- One of a series of inclined structural members which support the roof,
running from the exterior wall to the ridge board.
RAISED/CURLED
SEAMS - see SURFACE GRANULATION FAILURE.
RANDOM
SAMPLING - For multiple identical components such as windows,
doors, electrical outlets or heating registers. One per room is chosen
at random.
RECEPTACLE
- An electrical device to receive the prongs of a plug and which is connected
to an electric circuit.
REGISTER
- A fixture installed at the end of a duct which controls and directs
the flow of air into a room.
RELOCATE
LIGHT SWITCH - The bathroom light switch is located in the shower
receiving wall. This is hazardous. We recommend that the light switch
be moved to a safe location.
REPAIR
RECOMMENDED -An item which no longer functions as designed or
intended and should be repaired or replaced as necessary.
RIDGE
BOARD - The horizontal structural member at the top of a roof
where the rafters meet.
ROOF
PITCH - The degree of slope of a roof.
ROOMS
WITHOUT HEAT - Some areas of the structure are without heat.
Individual need may necessitate upgrading of this heating system.
ROTATION
- A significant number of older foundations were constructed without steel
reinforcement and with shallow footings. The weight of the structure was
placed on the outer edge of the foundation wall. This design commonly
results in some leaning of the foundation. Poor drainage is often times
the catalyst for rotation. Rotation does not necessarily mean that the
foundation has failed. It does weaken the foundation and it is more vulnerable
to excessive moisture conditions and seismic activity. The foundation
can be repaired. However, if left unattended, this condition will worsen
and may eventually result in a failure of the foundation which would require
replacement.
ROUTE
DOWNSPOUTS - All downspouts that do not terminate within drain
lines should be routed sufficiently away from the foundation to prevent
puddling and pooling and subsequent seepage through the foundation and
into the basement, garage and/or subarea.
ROUTE
TEMPERATURE AND PRESSURE RELIEF VALVE - We recommend that the
water heater temperature and pressure relief valve be routed to an approved
drain or safely to the exterior. This will help limit damage in the event
of a release of the relief valve.
RUNNING
SPLICE - An electrical connection made without proper protection.
We recommend that all of these connections be repaired and be mechanically
protected.
RVAC
UNIT - A single unit which supplies heating, venting and air
conditioning.

S
S-TRAP
- A sink drain line configuration in which the piping beyond the trap
runs vertically instead of horizontally. This can cause the water in the
trap to be siphoned out, allowing sewer gas to enter the occupied interior.
We recommend that the pipe after the trap be repaired so that it runs
horizontally with a slight downward slope until it joins the main drain
and vent piping, or that an approved mechanical vent be installed.
SCREEN
DOWNSPOUT OPENINGS - All downspout openings should be screened
to help prevent debris blockages and subsequent drainage failures within
these lines or the drain lines into which they terminate.
SETTLEMENT
- Settlement is that instance in which some portion of the foundation
drops below the original "as built" grade. This occurs as a
result of a loss of bearing compaction of fill, erosion of supporting
soil, and/or dehydration (shrinkage of supporting soil)
SHAKES
- Handsplit shingles.
SHEATHING
- The material used to cover the outside wall of a frame house or timber
roof.
SHOWER
RECEIVING WALL - The walls surrounding a shower which, because
of their orientation in relation to the shower head, are likely to be
wetted by the direct or indirect spray from that shower head.
SIDING
EMBEDDED IN THE GRADE - Exterior siding embedded in the exterior
grade is subject to moisture damage and pest control problems. We recommend
that this condition be corrected. Any damaged material found in the Course
of this work should be replaced.
SIGN
OF SIGNIFICANT NON-PERFORMANCE REQUIRING IMMEDIATE CORRECTION
- A system or component which no longer functions as designed and intended.
All Such items require immediate correction.
SILL
PLATE - Framing lumber placed on and around the foundation to
support exterior wall studs and outer floor joists.
SILT
MARKS - When a subarea gets wet enough for water to pond, it
can leave a sediment deposit on the foundation walls and foundation area
support piers.
SOFFIT
- The underside of an overhang of structural members, such as staircases,
beams and eaves.
SOIL
CONTAMINATION - Soil can be contaminated from leaking underground
storage tanks, illegal dumping, poorly contained landfills or hazardous
waste spills. Contaminated soil can be a health hazard, especially for
children. Qualified individuals would have to be retained for evaluation
and a determination of what corrective steps may be necessary.
SOIL
PIPE - Pipe carrying organic waste.
SPALLING
- Breaking off of the surface of brick or concrete.
SPLITS/CRACKS/TEARS
- A roofing surface condition conducive to moisture penetration and subsequent
leakage. These need to be repaired as necessary to prevent leakage.
STAIR
RAILING UPGRADE - Stairs with four or more steps should have
a safety railing. We recommend that an approved handrail be installed.
STAIR/LANDING
MOISTURE MEMBRANE FAILED - The moisture membrane has failed.
Water has penetrated through the membrane. There may be damaged framing
below. All damaged material must be replaced or the damage may spread.
Moisture must be prevented from penetrating the framing or additional
damage will occur. Our primary recommendation is to install a new moisture
membrane. This will stop any further leakage and subsequent damage. It
may be possible to seal the surface above, thereby, hopefully stopping
further water penetration. However, there is no guarantee that sealing
the surface will work and this repair will require frequent maintenance.
STUD
- A vertical, framing member in a wall or partition, usually spaced from
twelve to sixteen inches apart.
SURFACE
GRANULATION FAILURE - An indication of roofing surface wear due
to exposure. This wear will continue and leaks may eventually develop.
This condition is one indication that the roof is nearing the end of its
useful life. Until the roof is replaced, it should be periodically examined
by a qualified and licensed roofing contractor for indications of further
wear significant enough to result in moisture penetration and repairs
should be made as necessary.

T
TEMEPERATURE/PRESSURE
VALVE - A safety valve designed to release excess temperature
and pressure. Commonly used in water heaters and steam boilers.
THERMOSTAT
- An automatic heating/cooling control device. Some units are controlled
by clocks to set back the temperature during certain time periods as a
fuel-saving measure.
TILE
ROOF - Fired clay, stone or concrete roofing material. Tile roofs
are highly resistant to wear and have a life expectancy of fifty plus
years. However, problems can develop and these problems need attention
in order to prevent leakage. Walking on a tile roof may result in some
tile breakage; therefore, we examine tile roofs from ground level and
other vantage points. We look for cracked and missing tiles and cracked
and deteriorated tile mortar joints. We also examine the visually accessible
connection and penetration flashings for damage and defects. Problems
in these areas create opportunities for leakage and must be corrected
to prevent moisture penetration. The watertightness of a tile roof depends
to a large degree on the condition of the felt underlayment. The only
way to completely examine the underlayment is to remove all of the tile.
This, of course, is not practical. We inspect the felt underlayment by
lifting up the tiles at a random number of places. If the felt is found
to be deteriorated, it must be repaired. Repairing the underlayment requires
removing the tile and it may not be possible to reuse the tile. Often
times repairing the underlayment results in replacing all of the tile
and flashing around the connections and penetrations. Problems may be
present at areas we were unable to access. We recommend that tile roofs
be periodically examined by a qualified and licensed roofing contractor.
Occasionally tile roofing surfaces are installed directly over the sheathing
without an underlayment. An underlayment provides a moisture barrier between
the tile and the attic. The manufacturer's specifications may permit this
method of installation; however, it is our opinion that without an underlayment,
a tile roof is subject to premature leakage. In such cases, we recommend
that the tile surface and the connections and penetrations be frequently
examined by a qualified and licensed roofing contractor for signs of damage
and leakage and repairs made if necessary.
TOILET
LOOSE - When a toilet is not securely fastened to the floor,
the wax ring seal can deteriorate, causing the toilet to leak. A leaking
toilet can damage the floor and the floor framing. A toilet can leak for
some time before the damage becomes visible. We recommend that the wax
ring seal be replaced now and the toilet be securely fastened before the
need for additional costly repairs becomes necessary.
TON
OF REFRIGERATION - A measure of the rate of refrigeration equal
to 12,000 BTU per hour.
TRAP
- A fitting to provide a liquid seal that prevents the back passage of
gases, without materially affecting the flow of sewage or water through
it.
TRANSITE
VENT – A pipe composed chiefly of asbestos and portland
cement used to carry products of combustion from gas fired appliances
safely to the exterior of a dwelling. Transite vents are not recognized
by present code. They are subject to failure because of their absorbency
and the effect of the products of combustion on the product binders. The
local building department may require replacement of these vents. Asbestos
has been determined by the U.S. Consumer Product Safety Commission to
be a health hazard. There are a number of choices available in dealing
with asbestos. They include leaving it alone, encapsulation and abatement.
Removal of this material is a specialized procedure and should be attempted
only by a qualified and licensed expert. Information regarding identification
of asbestos, its hazards and safe removal may be obtained from the U.S.
Consumer Product Safety Commission (800) 638-CPSC, Environmental Protection
Agency and other governmental agencies.
TRANSITION
BOOT - A rectangular box attached to the end of a duct into which
the register is placed.

U
UNDERLAYMENT
- Building material, generally paper or felt, used as a protection against
the passage of air and moisture.
UNDERSIZED
GAS CONNECTOR - We found an undersized gas connector at one or
more of the appliances. The diameter of the gas supply piping should be
no smaller than the inlet connection of the appliance. We recommend that
the connector be removed and an approved connector installed in accordance
with standard building practice.
UNSTEADY
DECK OR STAIRWAY - Movement due to a lack of cross bracing. We
recommend that additional structural members be installed as necessary
to eliminate this movement.
UPGRADE
DRAINAGE - We found excessive moisture in the foundation area.
This moisture can damage the foundation and framing, plumbing piping and
heating ducts. It is our opinion that there is either insufficient or
defective site drainage. We, therefore, recommend that a qualified and
licensed drainage engineer be contacted to design and install a perimeter
drainage system. This drainage system should collect the surface as well
as the subsurface waters approaching the foundation system, and divert
them to some type of central drainage collection or disposal point.
UPGRADE
THE SHOWER WALLS - We found bathroom shower wall material extends
only part way up the receiving walls. This construction detail is conducive
to moisture penetration into and subsequent damage in presently concealed
areas behind the shower walls. We found no outward indications of leakage
or damage. However, with access and an opportunity for examination, reportable
conditions may be discovered. If review of these inaccessible areas is
desired, this will be performed upon arrangement at an additional cost
to the interested parties at such time as access can be provided. Ideally,
the shower walls should be upgraded and extended above the shower arm.
UPGRADING
RECOMMENDED - These are changes that we feel would be beneficial
to the functional use of a system and/or component. They are not required.

V
VALLEY
- A depressed angle formed where two roof planes meet.
VAPOR
BARRIER - A material or paint applied to a wall, floor or ceiling
to prevent the passage of moisture. Plastic vapor barriers are sometimes
applied over the subarea soil. This helps create a dry air space between
damp soil and wood framing and limits the amount of moisture able to rise
into the framing, thereby reducing moisture damage. A plastic vapor barrier
also provides a reasonable surface upon which to crawl in the event of
needed access to a moist subarea. Finally, a plastic vapor barrier tends
to keep moist soil from drying out completely and reduces the subsequent
shrinkage and cracking that often occurs. This reduces the settlement
often associated with expansive soil subject to fluctuating moisture content.
VENT
(PLUMBING) - A pipe installed to provide a flow of air to or
from a drainage system and to minimize possibilities of trap siphonage
and back pressure.
VEGETATION
ENCROACHMENT - Vines and/or shrubbery that cover the exterior
finished siding, foundation vents, decks, stairways and electrical equipment.
This vegetation can cause damage. We recommend that all shrubbery against
sidewalls and foundation vents be cut back. Tree limbs and branches that
have overgrown or surround the electrical service entrance conductor wires
should be removed.
VOLTAGE
- Electric power. The greater the speed at which electrons travel, the
more power present (240 volts is more powerful than 120 volts).
W
WARM
AIR SYSTEM - A heating system in which air is heated inside a
furnace and distributed throughout the house by means of convection.
WASTE
AIR GAP - A sink device installed between the dishwasher and
the drain line. Its purpose is to prevent the drawing of waste water into
the dishwasher.
WATT
- The amount of electricity flowing through a line, measured in terms
of watts. Volts multiplied by amps equals watts.
WATER
HAMMER - A sudden pounding noise in a piping system caused by
rapid pressure changes due to very quick closing of valves or other restrictions.
It is possible to correct this condition by installing an air chamber.
WATER
PRESSURE - 55 pounds per square inch is considered in the mid-range
of normal water pressure. Less than 30 psi is considered in the low-range
of normal water pressure. This usually occurs as a result of mineral deposits
building up inside the domestic water supply piping which restrict the
flow of water. The corroded lines eventually will need to be replaced.
Excessive water pressure (above 100 psi) puts unnecessary strain on the
water heater, water lines and fixtures which can result in leaks. We recommend
that a pressure reduction valve be installed in such instances.
WET
VENT - A vent that also serves as a drain. Most modern plumbing
practices do not permit wet vents. This condition should be corrected.
WOOD
FLOOR INSTALLED OVER AN UNKNOWN SURFACE - Ground level wooden
flooring that has been constructed on wood framing slightly elevated over
an unknown surface below. This type of construction is conducive to framing
damage within the concealed areas. We found no evidence to suggest the
presence of damage. However, with access and an opportunity for examination,
reportable conditions may be discovered. We recommend that portions of
the flooring be removed to provide sufficient access to determine the
presence and extent of any damage, and any necessary corrective measures.
|